![]() ![]() “If you want to find the secrets of the universe, think in terms of energy, frequency and vibration. Specifications: Range of dose rate indications, Sv/h 0.00 to 327. An even more advanced version, the GQ Geiger Counter Data Logger PRO software may be purchased at low cost from GQ Electronics LLC. This GQ GMC-600 Plus Geiger counter is a portable nuclear radiation detector. It supports programming, communication, and data retrieval between data loggers and a PC. I am hoping GQ support will chime in here with at least a plausible answer LOL! For professional data logging of radiation data, the GQ Geiger Counter Data Logger may be downloaded for free. LoggerNet is our main data logger support software package. GeigerLog does find the intended data, but ignores them anyway. Possibly testing data which GQ's expert programmers forgot to remove. My summary: The "Pro" software uses fake data. I just noticed a difference in the calibration settings in the standard viewer software and what is showing up in the Pro software can you explain why they are different? Is it fair to say that these GQ-numbers share a light on GQ's understanding of their Geiger What is the true sensitivity value in your opinion?Īnd in which firmwares do we find which "calibration 2 points, and at which locations? It certainly is NOT present in what you gave as the lastets firmware for a GMC-320+V5 RRe 5.63 ( )Īt least 24 bytes config memory will be needed for the 3 new extra "calibration" points. All you have to do is build such a lousy case for the latest GMC-600 that all sensitivity is ruined!īut it would be a miracle if GQ could build a counter, by any means, with a HIGHER sensitivity than the tube-manufacturer had determined. So while before GQ, by some magic, claimed a higher sensitivity than even the tube-manufacturer, now they are claiming a much worse sensitivity. Now this expensive tube has become 2.1 fold worse, being almost on par with the much cheaper M4011 tube?Īnd before the 420, GQ had the very same tube firmware-defined at 379.Īnd this while the tube manufacturer had never changed their specification of the tube, which had been and still is 348 CPM/(µSv/h) The firmware as recent as 2.42 had this at 420!!! Then the magnitude of the sensitivity is a surprise. So essentially you don't need 6, nor 5, nor 3 calibration points - but just a single one! Then all 5 value-pairs (where is the 6th, which was previously declared to be so essential?) code for the same 200 CPM/(µSv/h). If you take the inverse of sensitivity, you end with what GQ is using as a "calibration" factor.įirst note that you need Dose- rates, thus it should not be "µSv" but "µSv/h". Likewise for the other points I show all in the table. I am calculating the tube Sensitivity from these values, which results simply from the division of CPM by µSv/h, so e.g. The "6 calibration points" shown above, read-out from a 600+ counter with the "GQ Pro software", yield interesting but nonsensical data. ![]() There are more miracles than meets the eye! 5.61: 05-21-2020: 29501: GQ Geiger Counter Data Logger PRO works on many third party Geiger counters and all GQ GMC Geiger Counters. “If you want to find the secrets of the universe, think in terms of energy, frequency and vibration.” I tried to register using Windows 10 and GQ GMC Data Logger V5.56. ![]() When are you going to update this software? Last update was 2020, many of us have paid for it but it's features are far surpassed by the free GeigerLog software?įor instance there are now 6 calibration points in the latest firmware of my 600+ why is #6 point greyed out in the Pro software? The GMC Data Logger PRO software extended much more capabilities from GMC-300E. GQ GMC Data Logger PRO Software feature requests Use Data Viewer is free for all GQ GMC series Geiger Counter.GQ Electronics Technical Support Forum - GQ GMC Data Logger PRO Software feature requests That because Data Logger Pro is a generic software. Geiger Counter is an enhanced version of GMC-320. The Baud rate must be 115200 in Data Logger PRO software.Īlso, make sure your GMC-320+V4 set the baud rate to 115200 too. GQ Geiger Counter Data Logger PRO V5.61: Mar-08-2021: 25861: The software is used for GQ Geiger Counter data log. Click here to see GQ Geiger Counter Selection Guide. How to restore Steam library.Steam library data from. System Utilities downloads - GQ Geiger Counter Data Logger PRO by GQ Electronics and many more programs. You can check the comport number from Data Viewer since it works.Ģ. Download gq gmc data logger pro for free. GQ GMC-500 demo software is a 1:1 to actual GMC-500 unit. The USB port communicates with the GQ GMC-500 demo software and the GQ Geiger Counter Data Viewer software. The mainboard also has a real-time clock on board for time-related data logging purposes. The Data Logger PRO needs two settings for GMC-320+V4.ġ. The service is free to GQ GMC users with unlimited history data storage space. It will register but next time it loads shows unregistered. When try to use with data logger It does not work? running on win7 64bit. GQ Electronics Technical Support Forum - Data Logger GQ Geiger Counter Data Logger PRO (works on all Geiger Counter) 2.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |